Shielding paint HSF74 | Without preservative

Pure silicate paint with an absolute modicum of ingredients, also without a preservative agent. To be recommended only with an allergy against preservative agents. Based on potassium silicate. As a pure silicate paint with limited moisture resistance, therefore for interior use only. Because of a pH-value of 12 (superalkaline), application only with protective equipment. Higly breathable, solvent free, neutral odor, low-emission.

Pure silicate paint with an absolute modicum of ingredients, also without a preservative agent. To be recommended only with an allergy against preservative agents. Based on potassium... read more »
Close window
Shielding paint HSF74 | Without preservative

Pure silicate paint with an absolute modicum of ingredients, also without a preservative agent. To be recommended only with an allergy against preservative agents. Based on potassium silicate. As a pure silicate paint with limited moisture resistance, therefore for interior use only. Because of a pH-value of 12 (superalkaline), application only with protective equipment. Higly breathable, solvent free, neutral odor, low-emission.

Close filters
 
  •  
from to
  •  
  •  
  •  
  •  
  •  
  •  
  •  
No results were found for the filter!
YSHIELD® shielding paint HSF74 | HF+LF | 1 liter YSHIELD® shielding paint HSF74 | HF+LF | 1 liter
Pure silicate paint with an absolute modicum of ingredients, also without a preservative agent. To be recommended only with an allergy against preservative agents. Based on potassium silicate . As a pure silicate paint with limited moisture resistance, therefore for interior use only . Because of a pH-value of 12 (superalkaline), application only with protective equipment. Higly breathable, solvent free, neutral odor, low-emission . Screening attenuation : One layer 39 dB , two layers 45 dB . The shielding attenuation is regularly tested in our own EMC laboratory. We have measurement setups due to the following standards: ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07. Common: Our shielding paints, shielding with carbons have many advantages, see common characteristics . Application (coverage): Interior (7.5 m²/l). Underground: Interior: Good adhesion on absorbent, untreated, preferably mineral undergrounds like chalk, silicate, clay, etc.. Restricted use on absorbent emulsion paints, wallpapers, etc., please check first! Not usable on gypsum based substrates! Top coating: Preferably covered with plastic bonded, water-based emulsion paints or dispersion silicate paints. We restricted recommend pure mineral paints (clay, loam, chalk, silicate). Please find appropriate product recommendations in the technical data sheet. Grounding : Must be grounded! We recommend interior the grounding strap EB2 plus grounding plate GW (GB) plus GP, exterior the fiber additive AF3 plus the grounding plate GE. Ingredients: Potassium silicate, graphite, water, carbon black, emulsifier, defoamer, cellulose, no preservative agent. Technical data: VOC-content: 0.1 g/l (the EU limit value for category A/a is 30 g/l from 2010). Sd-value: 0.02 m. Ph-value: 12. Adhesive tensile strenght: 1.7 N/mm². Shelf live: 12 months. Color: Black. More technical details in our table overview .
Content 1 l
59.90EUR *

Stock status:

Add to wishlist
YSHIELD® shielding paint HSF74 | HF+LF | 5 liter YSHIELD® shielding paint HSF74 | HF+LF | 5 liter
Pure silicate paint with an absolute modicum of ingredients, also without a preservative agent. To be recommended only with an allergy against preservative agents. Based on potassium silicate . As a pure silicate paint with limited moisture resistance, therefore for interior use only . Because of a pH-value of 12 (superalkaline), application only with protective equipment. Higly breathable, solvent free, neutral odor, low-emission . Screening attenuation : One layer 39 dB , two layers 45 dB . The shielding attenuation is regularly tested in our own EMC laboratory. We have measurement setups due to the following standards: ASTM D4935-10, IEEE Std 299-2006, IEEEE Std 1128-1998, ASTM A698/A698M-07. Common: Our shielding paints, shielding with carbons have many advantages, see common characteristics . Application (coverage): Interior (7.5 m²/l). Underground: Interior: Good adhesion on absorbent, untreated, preferably mineral undergrounds like chalk, silicate, clay, etc.. Restricted use on absorbent emulsion paints, wallpapers, etc., please check first! Not usable on gypsum based substrates! Top coating: Preferably covered with plastic bonded, water-based emulsion paints or dispersion silicate paints. We restricted recommend pure mineral paints (clay, loam, chalk, silicate). Please find appropriate product recommendations in the technical data sheet. Grounding : Must be grounded! We recommend interior the grounding strap EB2 plus grounding plate GW (GB) plus GP, exterior the fiber additive AF3 plus the grounding plate GE. Ingredients: Potassium silicate, graphite, water, carbon black, emulsifier, defoamer, cellulose, no preservative agent. Technical data: VOC-content: 0.1 g/l (the EU limit value for category A/a is 30 g/l from 2010). Sd-value: 0.02 m. Ph-value: 12. Adhesive tensile strenght: 1.7 N/mm². Shelf live: 12 months. Color: Black. More technical details in our table overview .
Content 5 l (49.98EUR * / 1 l)
249.90EUR *

Stock status:

Add to wishlist

* All prices are gross prices which include tax, in addition shipping costs. Copyright © 2016 YSHIELD GmbH & Co. KG