Electrical products | Cables

Close filters
 
  •  
from to
  •  
  •  
No results were found for the filter!
 Shielded cable (N)YM(St)-J | 3 x 1.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 3 x 1.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 1.80EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 3 x 2.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 3 x 2.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.20EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 5 x 1.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 5 x 1.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.20EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 3 x 1.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 3 x 1.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.50EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 5 x 2.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 5 x 2.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.00EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 3 x 2.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 3 x 2.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.30EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 5 x 1.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 5 x 1.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.50EUR *

Stock status:

Add to wishlist
 Shielded cable (H)05VV-F3G | White 3 x 0.75 mm² | 1 meter Shielded cable (H)05VV-F3G | White 3 x 0.75 mm² | 1 meter
Shielded, very flexible cable for non-fixed electrical devices for the protection against low-frequency electric fields (LF). To reduce the magnetic field , the conductors are twisted 15 times per meter! Technical data Wire count, cross section: 3 x 0.75 mm² Current load according to IEC 320-1: 6 A Nominal voltage : 250 V / 50 Hz Color: White Outer diameter: 6.6 mm Protection class 1 (with ground wire) Construction 1) Copper conductors fine-stranded; 2) Insulation: Polyvinylchloride; 3) Drain wire: Copper: 0.34 mm²; 4) Screen: Plastic-coated aluminum band; 5) Outer sheath: Polyvinylchloride;
Content 1 lm
From 3.53EUR *

Stock status:

Add to wishlist
 Shielded cable (H)05VV-F3G | White 3 x 1.5 mm² | 1 meter Shielded cable (H)05VV-F3G | White 3 x 1.5 mm² | 1 meter
Shielded, very flexible cable for non-fixed electrical devices for the protection against low-frequency electric fields (LF). To reduce the magnetic field , the conductors are twisted 15 times per meter! Technical data Wire count, cross section: 3 x 1.5 mm² Current load according to IEC 320-1: 16 A Nominal voltage : 250 V / 50 Hz Color: White Outer diameter: 8.4 mm Protection class 1 (with ground wire) Construction 1) Copper conductors fine-stranded; 2) Insulation: Polyvinylchloride; 3) Drain wire: Copper: 0.34 mm²; 4) Screen: Plastic-coated aluminum band; 5) Outer sheath: Polyvinylchloride;
Content 1 lm
From 4.12EUR *

Stock status:

Add to wishlist
Adapter C13 to two pole C7 | D3223 Adapter C13 to two pole C7 | D3223
C13 to two pole C7
12.30EUR *

Stock status:

Add to wishlist
Adapter C13 to three pole C5 | D3245 Adapter C13 to three pole C5 | D3245
C13 to three pole C5
12.30EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D3381, 2 m white Plug with shielded cable and free end D3381, 2 m white
Technical data Length: 2 m Wire diameter: 0.75 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (7.35EUR * / 1 lm)
14.70EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D2828, 2 m black Plug with shielded cable and free end D2828, 2 m black
Technical data Length: 2 m Wire diameter: 1.0 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (7.55EUR * / 1 lm)
15.10EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D3368, 3 m black Plug with shielded cable and free end D3368, 3 m black
Technical data Length: 3 m Wire diameter: 0.75 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 3 lm (5.50EUR * / 1 lm)
16.51EUR *

Stock status:

Add to wishlist
 Shielded power cord D2806, 2 m black Shielded power cord D2806, 2 m black
Technical data Length: 2 m Wire diameter: 1.0 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (9.00EUR * / 1 lm)
18.00EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D2920, 4 m white Plug with shielded cable and free end D2920, 4 m white
Technical data Length: 4 m Wire diameter: 0.75 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 4 lm (5.33EUR * / 1 lm)
21.30EUR *

Stock status:

Add to wishlist
 Shielded power cord D3662, 3 m white Shielded power cord D3662, 3 m white
Technical data Length: 3 m Wire diameter: 1.0 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 3 lm (7.17EUR * / 1 lm)
21.50EUR *

Stock status:

Add to wishlist
Geschirmte Verlängerungsleitung D3640, 3 m schwarz Geschirmte Verlängerungsleitung D3640, 3 m schwarz
Technische Daten Länge: 3 m Kabelquerschnitt: 1,5 mm² Farbe: Schwarz Gemeinsame Daten aller Kabel Mit Kabeln (H)05VV-F3G zur Abschirmung niederfrequenter elektrischer Wechselfelder. Zur Minderung des magnetischen Feldes sind die Adern 15 mal pro Meter verdrillt. Anschlußspannung: 250 V / 50 Hz Schutzklasse 1 (mit Schutzleiter) Strombelastung 0,75 mm²: 6 A Strombelastung 1,0 mm²: 10 A Strombelastung 1,5 mm²: 16 A
Content 3 lm (7.37EUR * / 1 lm)
22.10EUR *

Stock status:

Add to wishlist
 Shielded extension cable D3425, 5 m white Shielded extension cable D3425, 5 m white
Technical data Length: 5 m Wire diameter: 1.5 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 5 lm (5.58EUR * / 1 lm)
27.91EUR *

Stock status:

Add to wishlist

* All prices are gross prices which include tax, in addition shipping costs. Copyright © 2016 YSHIELD GmbH & Co. KG