Electrical products

Demand switches in a fuse box will switch of electricity supply when there is no load on the circuit that needs power. Shielded power outlet strips with shielded connection cables will achieve a field-free power distribution. Shielded installation boxes combined together with shielded installation cables wont create electrical fields and should always be used for new installations.

Demand switches in a fuse box will switch of electricity supply when there is no load on the circuit that needs power. Shielded power outlet strips with shielded connection cables will... read more »
Close window
Electrical products

Demand switches in a fuse box will switch of electricity supply when there is no load on the circuit that needs power. Shielded power outlet strips with shielded connection cables will achieve a field-free power distribution. Shielded installation boxes combined together with shielded installation cables wont create electrical fields and should always be used for new installations.

Close filters
 
  •  
from to
  •  
  •  
  •  
No results were found for the filter!
TIP
 Demand Switch Comfort NA7 with VDE mark Demand Switch Comfort NA7 with VDE mark
Our top-selling Demand Switch with VDE mark. Innovation: Various granted and pending patents are an impressive proof of our technical superiority in comparison with the state-of-the-art compared with other devices on the market. Safety: The Demand Switch NA7 comfort was the first "decoupler" ever to be certified the VDE (the Association for Electrical, Electronic & Information Technologies) certificate for fulfilling the severe safety regulations. VDE identification number: 40000677. Practical efficiency: The Gigahertz Solutions Demand Switches have been installed by many experienced electrical engineering technicians for many years. They are on the recommendation lists of renowned building biologists and are in use in thousands of households every day. Technical data Nominal voltage / capacity: 230 VAC +/- 10 %, 16 Amp., 2300 watt filament lamp load. Mechanical durability of the relay: approx. 15.000.000 operating cycles. Residual ripple (nominal/typical/maximum): Monitoring voltage: Building biology compatible DC voltage (max. 8mA / 230 VDC). Single-poled disconnection for optimum operator protection. A minimum residual ripple is quaranteed by a low resistance PTC connection to the terminal "neutral". Warranty: 2 years. Included in delivery: Demand Switch, control lamp, detailed instructions manual. How a demand switch works Electricity has become indispensable for every day life. The use of electricity inevitably causes alternating electrical and magnetic fields. The effect of these electrical and magnetic fields on the human oraganism has been the subject-matter of many international studies with some concerning results. At present, the "safe" levels of electric and magnetic fields are still to be determined, but it is now agreed by many doctors and scientists that the levels should be reduced on the principle of ALARA (As Low As Reasonably Achievable). Magnetic fields should be measured and any wiring faults corrected. Electric fields can only be reduced by using electrically screened cables or using a "Demand Switch" whichremove the high (230 volt) supply when there is no load on the circuit that needs power. This is particularly useful at night-time. A reliable demand switch optimised according to building biology criteria can substantially reduce your daily exposure without your being inconvenienced. It is for this reason that many experts...
188.14EUR *

Stock status:

Add to wishlist
 Multiple socket outlet D6700, 4 x switched Multiple socket outlet D6700, 4 x switched
Professional quality! 4 schuko inserts switched. Casing: Robust anodized aluminium frame. 2-poled switch . Socket outlets black, 45° positioned with children protection . Shielded power connection cord: 2 meter, 3 x 1.0 mm² . Integrated decoupling filter. Connection voltage: 250 V / 50 Hz. Current load: 10 A . Size: 317 x 52 x 45 mm.
49.50EUR *

Stock status:

Add to wishlist
 Multiple socket outlet D6744, 4 x switched, 2 x unswitched Multiple socket outlet D6744, 4 x switched, 2 x unswitched
Professional quality! 4 schuko inserts switched, 2 inserts unswitched. Casing: Robust anodized aluminium frame. 2-poled switch . Socket outlets black, 45° positioned with children protection . Shielded power connection cord: 2 meter, 3 x 1.0 mm² . Integrated decoupling filter. Display for over voltage protection funktion PRO-TECTOR: Line filter with an attenuation of 50 dBm; HF-filter over 80 MHz. Connection voltage: 250 V / 50 Hz. Current load: 10 A . Size: 572 x 52 x 45 mm.
99.50EUR *

Stock status:

Add to wishlist
TIP
 Multiple socket outlet D6788, 9 x switched Multiple socket outlet D6788, 9 x switched
Professional quality! 9 schuko inserts switched. Casing: Robust anodized aluminium frame. 2-poled switch . Socket outlets black, 45° positioned with children protection . Shielded power connection cord: 2 meter, 3 x 1.5 mm² . Integrated decoupling filter. Connection voltage: 250 V / 50 Hz. Current load: 16 A . Size: 572 x 52 x 45 mm.
95.00EUR *

Stock status:

Add to wishlist
 Mounting angle D6867 Mounting angle D6867
With this mounting angles, all our professional multiple socket outlets D6700, D6766 and D6788 can be fixed easy in different angles.
6.40EUR *

Stock status:

Add to wishlist
 Shielded in-wall box 41 mm D4448 Shielded in-wall box 41 mm D4448
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. With snap-lock coupling, as one gang box or switch box under plaster. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
6.00EUR *

Stock status:

Add to wishlist
 Shielded in-wall box 61 mm D4426 Shielded in-wall box 61 mm D4426
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. With snap-lock coupling, as one gang box or switch box under plaster. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
6.60EUR *

Stock status:

Add to wishlist
 Shielded cavity-wall box 47 mm D4483 Shielded cavity-wall box 47 mm D4483
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. One gang box or switch box for plate thickness from 7-35 mm. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
8.04EUR *

Stock status:

Add to wishlist
 Shielded cavity-wall box 59 mm D4461 Shielded cavity-wall box 59 mm D4461
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. One gang box or switch box for plate thickness from 7-35 mm. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
9.10EUR *

Stock status:

Add to wishlist
 Shielded cavity-wall lamp connection box D4606 Shielded cavity-wall lamp connection box D4606
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. Connection box for lamps . Diameter 35 mm, Depth 45 mm. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
11.10EUR *

Stock status:

Add to wishlist
 Shielded junction casing D4505 Shielded junction casing D4505
Shielded with conductive vacuum coating. Connection wire 1.5 mm², solid, isolated. Junction casing for hollow or brick walls . 107 x 107 x 53 mm. Standard mounting distances. Common characteristics Conductable coated brick wall and hollow wall installation sockets to effectably confine electrical alternating fields. Especially suited for hospitals, computer rooms and other sensentive areas desiring to confine electrical alternating fields. Special conductive metal vacuum coating for shielding against electrical alternating fields Guaranteed standard combination 60 mm Connecting wire 1.5 mm2 (copper, massive, rigid, transparent isolated), quick assembly in push-wire connector Installation of the insertions with screws and other standard combinations Brick wall installation socket insertion boxes, shielded Snap-lock coupling with standard distance 71 mm, break out opening up to size 16, Polystyrene (PS). Hollow wall installation socket insertion box, shielded Can be used for a plate thickness from 7 to 35 mm, various break out openings, pre-mounted insertion socket screws, snap-lock spacer, polypropylene (PP, halogen free). Junction casing, shielded (Hollow wall and brick wall installation) Can be used as a brick wall socket insertion box or for hollow wall sockets for a plate thickness from 7 to 35 mm, various break out openings for cable installations, creating a wall opening by milling 4 holes 35 mm (drill template), incl. lid screws and shielded lid with additional earth wire connections, polypropylene (PP, halogen free).
27.41EUR *

Stock status:

Add to wishlist
 Insulation sleeve D4685 | 100 pieces Insulation sleeve D4685 | 100 pieces
Length 10 cm. Transparent for drain wire. For insulation of the blank drain wire of the installation cables.
Content 100 Stück (0.09EUR * / 1 Stück)
9.10EUR *

Stock status:

Add to wishlist
 Push-wire connector D4628 | 50 pieces Push-wire connector D4628 | 50 pieces
To connect the box wire with the ground wire of the shielded cable. 5 x 1.0 mm² up to 2.5 mm² Transparent
Content 50 Stück (0.21EUR * / 1 Stück)
10.70EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 3 x 1.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 3 x 1.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 1.80EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 3 x 2.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 3 x 2.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.20EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 5 x 1.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 5 x 1.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.20EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 3 x 1.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 3 x 1.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 2.50EUR *

Stock status:

Add to wishlist
 Shielded cable (N)YM(St)-J | 5 x 2.5 mm² | 1 meter Shielded cable (N)YM(St)-J | 5 x 2.5 mm² | 1 meter
Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209) PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG Direct current resistance to DIN VDE 0295 Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V Bending radius accoording to DIN VDE 0298: 4 x D Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad) Variants Wire count / cross section Outer diameter Weight 3 x 1.5 mm² 10.5 mm 154 g/m 3 x 2.5 mm² 12.0 mm 217 g/m 5 x 1.5 mm² 12.0 mm 208 g/m 5 x 2.5 mm² 13.5 mm 208 g/m Construction 1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering; 4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.00EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 3 x 2.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 3 x 2.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.30EUR *

Stock status:

Add to wishlist
 Shielded cable (N)HXMH(St)-J | 5 x 1.5 mm² | 1 meter Shielded cable (N)HXMH(St)-J | 5 x 1.5 mm² | 1 meter
Shielded installation cables for the protection against low-frequency electric fields (LF) . With improved properties in the event of fire. For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete. Technical data Wire count, cross section: 3 x 1.5 mm² Length: By the meter / max. 50 m on one roll possible Outer diameter: 10.2 mm Weight: 148 g/m Calorific potential: 0.43 kWh/m No PVC because of halogen-free polymer mixture (according to DIN VDE 0250 part 214) Free of plasticizers for ecological constructions Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 cat. C Nominal voltage U0/U: 300/500 V, current load according to VDE 0100 Construction according to DIN VDE 0250 part 204/209, marking according to DIN VDE 0293 Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 3500 V Bending radius accoording to DIN VDE 0298: 4 x D Operating temperature -30°C to +70°C, cabling temperature -5°C to +70°C Construction 1) Solid conductor; 2) Insulation: cross linked polyethylene; 3) Common inner covering; 4) (St)-Screen: foil with 1.13 mm wire; 5) Outer sheath: halogen free polymer compund; Information on installing Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow , in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube . There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector . Do not use shielded and unshielded cables at the same time.
Content 1 lm
From 3.50EUR *

Stock status:

Add to wishlist
 Shielded cable (H)05VV-F3G | White 3 x 0.75 mm² | 1 meter Shielded cable (H)05VV-F3G | White 3 x 0.75 mm² | 1 meter
Shielded, very flexible cable for non-fixed electrical devices for the protection against low-frequency electric fields (LF). To reduce the magnetic field , the conductors are twisted 15 times per meter! Technical data Wire count, cross section: 3 x 0.75 mm² Current load according to IEC 320-1: 6 A Nominal voltage : 250 V / 50 Hz Color: White Outer diameter: 6.6 mm Protection class 1 (with ground wire) Construction 1) Copper conductors fine-stranded; 2) Insulation: Polyvinylchloride; 3) Drain wire: Copper: 0.34 mm²; 4) Screen: Plastic-coated aluminum band; 5) Outer sheath: Polyvinylchloride;
Content 1 lm
From 3.53EUR *

Stock status:

Add to wishlist
 Shielded cable (H)05VV-F3G | White 3 x 1.5 mm² | 1 meter Shielded cable (H)05VV-F3G | White 3 x 1.5 mm² | 1 meter
Shielded, very flexible cable for non-fixed electrical devices for the protection against low-frequency electric fields (LF). To reduce the magnetic field , the conductors are twisted 15 times per meter! Technical data Wire count, cross section: 3 x 1.5 mm² Current load according to IEC 320-1: 16 A Nominal voltage : 250 V / 50 Hz Color: White Outer diameter: 8.4 mm Protection class 1 (with ground wire) Construction 1) Copper conductors fine-stranded; 2) Insulation: Polyvinylchloride; 3) Drain wire: Copper: 0.34 mm²; 4) Screen: Plastic-coated aluminum band; 5) Outer sheath: Polyvinylchloride;
Content 1 lm
From 4.12EUR *

Stock status:

Add to wishlist
Adapter C13 to two pole C7 | D3223 Adapter C13 to two pole C7 | D3223
C13 to two pole C7
12.30EUR *

Stock status:

Add to wishlist
Adapter C13 to three pole C5 | D3245 Adapter C13 to three pole C5 | D3245
C13 to three pole C5
12.30EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D3381, 2 m white Plug with shielded cable and free end D3381, 2 m white
Technical data Length: 2 m Wire diameter: 0.75 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (7.35EUR * / 1 lm)
14.70EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D2828, 2 m black Plug with shielded cable and free end D2828, 2 m black
Technical data Length: 2 m Wire diameter: 1.0 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (7.55EUR * / 1 lm)
15.10EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D3368, 3 m black Plug with shielded cable and free end D3368, 3 m black
Technical data Length: 3 m Wire diameter: 0.75 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 3 lm (5.50EUR * / 1 lm)
16.51EUR *

Stock status:

Add to wishlist
 Shielded power cord D2806, 2 m black Shielded power cord D2806, 2 m black
Technical data Length: 2 m Wire diameter: 1.0 mm² Color: Black Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 2 lm (9.00EUR * / 1 lm)
18.00EUR *

Stock status:

Add to wishlist
 Plug with shielded cable and free end D2920, 4 m white Plug with shielded cable and free end D2920, 4 m white
Technical data Length: 4 m Wire diameter: 0.75 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 4 lm (5.33EUR * / 1 lm)
21.30EUR *

Stock status:

Add to wishlist
 Shielded power cord D3662, 3 m white Shielded power cord D3662, 3 m white
Technical data Length: 3 m Wire diameter: 1.0 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 3 lm (7.17EUR * / 1 lm)
21.50EUR *

Stock status:

Add to wishlist
Geschirmte Verlängerungsleitung D3640, 3 m schwarz Geschirmte Verlängerungsleitung D3640, 3 m schwarz
Technische Daten Länge: 3 m Kabelquerschnitt: 1,5 mm² Farbe: Schwarz Gemeinsame Daten aller Kabel Mit Kabeln (H)05VV-F3G zur Abschirmung niederfrequenter elektrischer Wechselfelder. Zur Minderung des magnetischen Feldes sind die Adern 15 mal pro Meter verdrillt. Anschlußspannung: 250 V / 50 Hz Schutzklasse 1 (mit Schutzleiter) Strombelastung 0,75 mm²: 6 A Strombelastung 1,0 mm²: 10 A Strombelastung 1,5 mm²: 16 A
Content 3 lm (7.37EUR * / 1 lm)
22.10EUR *

Stock status:

Add to wishlist
 Shielded extension cable D3425, 5 m white Shielded extension cable D3425, 5 m white
Technical data Length: 5 m Wire diameter: 1.5 mm² Color: White Common data of all cables With cables (H)05VV-F3G for the protection against low-frequency electric fields (LF). To reduce the magnetic field, the conductors are twisted 15 times per meter! Nominal voltage : 250 V / 50 Hz Protection class 1 (with ground wire) Current load 0.75 mm²: 6 A Current load 1.0 mm²: 10 A Current load 1.5 mm²: 16 A
Content 5 lm (5.58EUR * / 1 lm)
27.91EUR *

Stock status:

Add to wishlist

* All prices are gross prices which include tax, in addition shipping costs. Copyright © 2016 YSHIELD GmbH & Co. KG